Design Basis
1.1 Produced water’s application: Bottle drinking water
1.2 The capacity of produced water: 2000L /H
1.3 System Configuration: Pretreatment + One Stage Reverse Osmosis Desalination System.
1.4 Designed recovery: 50-65%.
1.5 Rejection rate:≥ 97%
1.6Voltage: 3 phases, 380V, 50Hz; Power: 5KW
1.7 Operation Process: Automatic Running
Purification Process
Raw water tank - Raw water Booster Pump - Mechanical Filter - Active Carbon Filter - Micron Filter - High Pressure Pump - RO Main System - Pure Water Tank
Features of Electric Control:
1)Inlet low pressure protection switch of high-pressure pump:
Linkage with the high-pressure pump, pressure below the set value, high-pressure pump will stop running.
2) The membrane inlet high pressure protection switch:
Linkage with the high-pressure pump, if operated high pressure too high, the membrane will be easy to get blocked, even penetrated. When the membrane system operating pressure exceeds the setting value, the high-pressure pump will stop running.
3) The reverse osmosis unit equipped with low pressure automatic flush valve:
Linkage with the high-pressure pump, set by the time relay, when the reverse osmosis unit start to work, the system auto startup, washing the film surface with large-flow, so the sediments on membrane surface washed away in time, to ensure the normal operation of membrane.
4) Raw water tank / pure water tank high and low level control switch
The raw water pump / high pressure pump linkage, the raw water tank at low level, the raw pump automatic shutdown for protection, when pure water tank full, high-pressure pump to stop.